**Jumper wires** | **Jumper wires** | ||
+ | |||
Jumper wires(fig 6) are used to make temporary electrical connections between the microcontroller and sensors. | Jumper wires(fig 6) are used to make temporary electrical connections between the microcontroller and sensors. | ||
Line 61: | Line 62: | ||
**Flashlight** | **Flashlight** | ||
+ | |||
A flashlight (fig 8) was used to provide light flash since the TSL2591 sensor does not have a built-in LED. It helps charge the phosphorescent stickers to simulate bioluminescence for testing. | A flashlight (fig 8) was used to provide light flash since the TSL2591 sensor does not have a built-in LED. It helps charge the phosphorescent stickers to simulate bioluminescence for testing. | ||
Line 127: | Line 129: | ||
===== 5. DISCUSSION ===== | ===== 5. DISCUSSION ===== | ||
The system, built with an Adafruit QT Py and TSL2591 sensor, successfully measured differences in light intensity between toxic and non-toxic samples. The dark box reduced outside light, improving the accuracy of the readings. Future improvements could include better wireless support and testing with real bioluminescent bacteria. | The system, built with an Adafruit QT Py and TSL2591 sensor, successfully measured differences in light intensity between toxic and non-toxic samples. The dark box reduced outside light, improving the accuracy of the readings. Future improvements could include better wireless support and testing with real bioluminescent bacteria. | ||
+ | ==Limitations include :== | ||
+ | The system only supports 2.4 GHz Wi-Fi, which limited wireless data transfer on 5 GHz networks. | ||
+ | |||
+ | The light sensor was not sensitive enough to detect weak bioluminescence. | ||
+ | |||
+ | Ambient light interference required full enclosure in a dark box. | ||
+ | |||
+ | Data had to be logged manually due to connectivity issues. | ||
+ | |||
+ | Phosphorescent stickers were used instead of real Vibrio fischeri; testing with actual bacteria is still needed for accurate validation. | ||