eolab:rs485_lorawan:start
Differences
This shows you the differences between two versions of the page.
Next revision | Previous revision | ||
eolab:rs485_lorawan:start [2022/02/11 20:36] – created jan001 | eolab:rs485_lorawan:start [2023/01/05 14:38] (current) – external edit 127.0.0.1 | ||
---|---|---|---|
Line 6: | Line 6: | ||
This prototype also includes a custom-made circuit board. | This prototype also includes a custom-made circuit board. | ||
- | {{gallery>: | + | {{gallery>: |
====== Soil Moisture Lora Node (Prototype v2) ====== | ====== Soil Moisture Lora Node (Prototype v2) ====== | ||
Line 12: | Line 12: | ||
The second prototype is more sophisticated and implements things that work in a more compact and also cleaner way. | The second prototype is more sophisticated and implements things that work in a more compact and also cleaner way. | ||
It is still based on the RFM95 HopeRF Module on 868 Mhz. It's using a 18650 LiPo battery and also includes a Solar Charger, so a Solar Cell can be hooked up. Furthermore, | It is still based on the RFM95 HopeRF Module on 868 Mhz. It's using a 18650 LiPo battery and also includes a Solar Charger, so a Solar Cell can be hooked up. Furthermore, | ||
- | {{ :eolab:sceme_node: | + | {{ eolab:rs485_lorawan:v2-m0_lora-node_2021-dec-15_10-45-12am-000_customizedview4115199873_jpg.png? |
Currently, we are running our final tests on these prototypes and will deploy some of these in the field for testing. One prototype, with a solar cell, is already running on our lab's terrace. | Currently, we are running our final tests on these prototypes and will deploy some of these in the field for testing. One prototype, with a solar cell, is already running on our lab's terrace. | ||
- | {{ :eolab:sceme_node: | + | {{ eolab:rs485_lorawan:v2-img_20220128_162416.jpg? |
The casing right now is not perfect and much bigger than it would be needed. | The casing right now is not perfect and much bigger than it would be needed. | ||
+ | |||
+ | ====== Soil Moisture Lora Node in Action ====== | ||
+ | |||
+ | We installed one of the prototypes v2 with a bigger solar cell on a field near Goch. It´s right next to the river Niers. Because it rained the last days before installation, | ||
+ | |||
+ | {{ : | ||
+ | {{ : | ||
+ | |||
+ | Because this particular field is used for cows in the summer, the wire needed to be buried underground. In the future the sensor node should be moved higher. | ||
+ |